Shanghai Lifeitest Co., Ltd

ECG Simulators

ECG Simulators

ECG simulator designed for ECG performance testing. Capable of adding noise, respiration and lead-off simulations. Flexible operation modes for standalone or PC software.Suitable for R&D and compliance testing.Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, GB 9706.225, GB 9706.227, YY 9706.247, YY1079, YY1139, YY0782, YY0885, JJG 760, JJG 1042, ANSI/AAMI EC11, ANSI/AAMI EC13

 

SECG 5.0 AIOBuilt-in test circuits as defined in ECG standardsAdjustable parameters and selectable options enable to verify DUT with flexibilityProvides NST noise simulation - Electrode Motion Artifact / Muscle Noise / Baseline WanderVarious signal simulations - Impedance Type Respiration, Wave Modulation Type (Baseline / Amplitude / Frequency) Respiration and lead-off simulationAuto Sequence function assists in conducting semi-automated testsLoads and plays recorded or programmed waveformsSoftware Development Kit (SDK) allows to develop customized or automated test software with less effortsOptional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criteriaWith Transmittance SpO2 Module (PPG-2TF-660)Simulates ECG and PPG signals to conduct SpO2 and PWTT (Pulse Wave Transit Time) testingAdjustable SpO2 parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of DUTsBuilds or loads the R curve of the SpO2 function to quickly verify products' performance and assist in comparing against competitorsBuilt-in 14 types of ambient light signals and respiratory variation simulation - add-on signals for more authentic testingSynchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithmsWith Reflectance SpO2 Module (PPG-2R-880/PPG-2R-940)Simulates ECG and PPG signals to conduct SpO2 and PWTT (Pulse Wave Transit Time) testingAdjustable SpO2 parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of DUTsBuilds or loads the R curve of the SpO2 function to quickly verify products' performance and assist in comparing against competitorsBuilt-in respiratory variation simulation - add-on signals for more authentic testingSynchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithmsWith Reflectance Green Light Heart Rate Module (PPG-1R-525)Outputs green light analog signals to simulate PPG signalsBuilt-in respiratory variation simulation - add-on signals for more authentic testingSynchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithmsEquipped with RCA to BNC ports to connect to an oscilloscope - outputs amplified and stable signals for viewing the voltage of AC analog signals of green light, optical signals received by the PPG-1R-525, and the switch status of green LED of DUTTesting Scenario

View as :

(1 - 2 out of 2)

1

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To XiuMei Chen
Shanghai Lifeitest Co., Ltd
* Subject
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838